3. You
are the network administrator of the RouterSim
global software Company. You receive a call
from a user who is unable to reach a server
at a remote site. After further review you
discover the following info:
Local PC 190.0.3.35/24
Default Gateway 190.0.3.1
Remote Server 190.0.5.250/24
You then conduct the following tests from the offending local PC:
Ping 127.0.0.1 - Unsuccessful
Ping 190.0.3.35 - Successful
Ping 190.0.3.1 - Unsuccessful
Ping 190.0.5.250 - Unsuccessful
Which of the following problems would create the test results listed
above?
A. TCP/IP not correctly installed
B. Local physical layer problem
C. NIC not functioning
D. Remote physical layer problem
Answer: A
If you cannot ping the loopback address of 127.0.0.1, then something
is wrong with the IP configuration of the host.
Todd Lammle,
best known for over 30 award winning Sybex
Study Guides on the Cisco and Microsoft networking
environments, teams up with Redmond Exams
to offer some of the toughest PREP Tests
available. The Sample Questions are from
our CCNA exam.
All
Exam questions are based on the Real Cisco
Exam questions!